Halsey Taylor OVL-II ER-Q Water Dispenser User Manual


 
10
OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F
97793C - 10/01
TROUBLESHOOTING & MAINTENANCE
Orifice Assembly: Mineral deposits on orifice can cause
water flow to spurt or not regulate. Mineral deposits may
be removed from the orifice by poking with a small round
file not over 1/8 diameter, or using a small diameter wire.
!
CAUTION:
DO NOT file or cut orifice
material.
Stream Regulator: If orifice is clean, regulate flow as in
Step 10 of the installation instructions. If replacement is
necessary, see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Cooler is
provided with lead-free connectors which utilize an o-ring
water seal. To remove tubing from the fitting, relieve water
pressure, push in on the gray collar while pulling on the
tubing. (See Figure 19) To insert tubing, push tube
straight into fitting until it reaches a positive stop (approxi-
mately 3/4).
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
PUSH IN COLLET
TO RELEASE TUBE
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS
SECURED
IN POSITION
!
CAUTION:
Cleaning of Aztec Gold Models
requires special care. Outer
surfaces must be cleaned with
mild detergent or a mixture of
vinegar and water only, rinsed and
wiped dry. Abrasive and acidic
cleaners may eventually damage
the Aztec Gold finish.
Figure 19  Quick Connect Fittings
Figure 21  Regulator Mounting Mechanism
Figure 20  Push Arm Mechanism
28