Model 290
Problem Cause Correction
POWER SECTION
With switch in Open circuit Check to see that unit is
POWER position, plugged in
the fryer is com-
Check the breaker or fuse
pletely inoperative at supply box
(NO POWER) Check voltage at wall
receptacle
Check MAIN POWER
switch; replace if defective
Check cord and plug
• Check 15 amp fuses
1203 1-6
Blown fuse or tripped Reset breaker or replace fuse
circuit breaker at supply
box or control panel
Blown fuse in PC board Replace glass fuse in board
Faulty POWER/PUMP switch. Check POWER/PUMP switch
per maintenance section on
the POWER/PUMP switch
Faulty cord and plug Check cord and plug
Check power at receptacle
Faulty drain switch Check drain switch per
maintenance section on
drain switches
Faulty PC Board Remove and replace control
panel
Faulty high limit control switch Check high limit control
switch per maintenance
section on the high limit
Drain valve open Close drain valve
Possible faulty temperature probe Replace temperature probe
Faulty contactor Check contactor per maintenance
section on contactors
HEATING OF SHORTENING SECTION
Shortening will not heat