Henny Penny 302 Fryer User Manual


 
enny
OEI
301l3~2l303
3-5.
F
(~o~ti~ue~)
If shortening is slow coming from faucet, it is possible that
the filter connecting the union on the filter tube line is not
tightened properly. If so, turn off the pump and use gloves
to tighten the union. This union will be hot. Severe burns
could result.
e. Wash down and scrub the sides of the frypot.
f. After the sides and bottom are cleaned, open the drain
valve.
7. Pump all of the shortening out of the filter pan and back
into the cookpot.
8. When the pump is pumping air only, move the pump
switch from PUMP to OFF.
9. Check the level of the shortening in the cookpot. Add
fresh shortening if necessary, until it reaches the level
indicator line on the rear wall of the cookpot.
Approximately 10 to 12 filterings can be made with one filter
paper envelope, depending on several conditions; the quan-
tity and type of product fried and filtered, the type of
breading used, and the amount of crumb accumulation left
inside the filter drain pan. When the filter screen assembly
and filter paper become clogged and the pumping flow rate
slows down, clean the screen assembly and change the filter
envelope.
10. If frying is to be continued at this time, move the main
power switch back to the “ON” position, and allow time
for reheating of the shortening.
The following steps will help prevent filter pump problems.
1. Make certain the filter paper envelope is properly in-
stalled over the filter screens. Make sure the open end
of the envelope is properly folded over and clamped in
place with the retaining clips so that the envelope is
sealed and crumbs cannot enter.
I
2. Make sure all the shortening has been pumped from the
filter lines and the pump by allowing the filter pump
motor to run until no shortening is coming from the
nozzle.
;-,;,?;I