4-2. TROUBLESHOOTING
(Continued)
Problem Cause Correction
Slow to decrease Condenser obstructed by dirt. Clean the Condenser.
in temperature (decline in
performance) Evaporator iced up. Perform a de-icing cycle.
Refrigerating problem Check refrigeration circuit and
components.
Display temperature does In Frigiprobe mode, the display Normal
not match the actual inlet air shows the product temperature.
temperature. (No alarm)
In timer mode, or hold mode, Ohm out the probe and check
the probe may be showing the the reading with the table on
wrong temperature. page 4-5. Change the probe if
it is out of tolerance.
Green compressor indicator Compressor and condenser fan
light on and the compressor do not work:
not working, or working - Faulty contactor Check contactor and change if
sometimes. neccessary.
- Faulty control board relay-no Replace control board.
voltage across terminals 10-11.
Compressor works, but condenser
fan does not:
- Faulty condenser fan Replace fan.
Compressor and condenser fan
work together:
- Faulty protection component Check items and replace if
for the compressor (overload neccessary.
protector, potential relay, start
and run capacitor)
- Faulty overload protector of Check fan and replace if
condenser fan. necessary.
4-3 100