Henny Penny BCC/BCR-140 Freezer User Manual


 
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350
4-2. TROUBLESHOOTING
(Continued)
Problem Cause Correction
Green compressor indicator Voltage across terminals 10-11
light off and compressor of control board:
is working. - Control board relay bad Replace control board.
No voltage across terminals 10-11
of control board:
- Faulty contactor.Replace contactor.
Green fan indicator light Voltage across terminals 8-9 of
on and fan(s) not working. control board.
- Fan or capacitor bad Replace fan or its capacitor.
- Fan thermo-switch tripped. Allow the fan motor to cool to
see if the fan comes back on.
If the fan does not come back
on, or it keeps tripping, re-
place the fan.
No voltage across terminals 8-9
of control board:
- Faulty control board relay. Replace control board.
All indicator lights off and Check electrical supply. Plug unit into receptacle, or
On/Off switch will not reset wall circuit breaker.
operate.
Fuse of control board blown. Change the fuse.
No voltage from the control Change the control board.
board transformer.
Connector between the control Check the connection.
board and display board not
connected properly.
Bad wire in the connector between Replace the connector.
the control board and display
board.