Henny Penny OFE/OFG-342 Fryer User Manual


 
Model OFE/OFG/OEA/OGA-341, 342
2-9. IGNITION MODULE During normal operation, the ignition modules send 24 volts to the
ignitors and gas valve. If a module does not sense a pilot flame,
the module starts the ignition process again. But, if a pilot light
goes out for longer that 10 seconds, or it goes out 3 times within 10
seconds, the module keeps the 24 volts from reaching the gas
valve. The burners shut down.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Figure 2-23 2. Remove the control panel and heat shield from control area.
Figure 2-23.
3. Using a 3/8 inch socket, remove the two nuts securing the
module. Figure 2-24.
Figure 2-24
4. Label and remove the wires at module. Figure 2-25.
5. Install new module in reverse order.
Figure 2-25
1003 2-9