1-3. TROUBLESHOOTING To isolate a malfunction, proceed as follows:
1. Clearly define the problem or symptom and when it
occurs.
2. Locate the problem in the Troubleshooting table.
3. Review all possible causes, then one at a time work
through the list of corrections until the problem is solved.
If maintenance procedures are not followed correctly,
injuries and/or property damage could result.
PROBLEM CAUSE CORRECTION
With the switch in Open circuit Check to see if unit is plugged in
the ON position,
fryer is completely Check breaker or fuse at supply box
inoperative
Check power switch per Power Switch
Section; replace if defective
Check voltage at wall receptacle
Check cord and plug
Shortening will not Faulty contactor Check contactor per Heating Contactors
heat but lights are on (elec. model) Section
Faulty gas control Check gas control valve per Gas Control
valve (gas model) Valve Assembly Section
Faulty temperature Check temperature probe per Temperature
probe Probe Replacement Section; “E6”
Faulty high limit Check high limit per the appropriate High
Temperature Limit Control Section; “E10”
Faulty drain switch Check drain switch per Drain Microswitch
Section; “E15"
1-2 1003