Model OFE/OFG/OEA/OGA-341, 342
1-3. TROUBLESHOOTING To isolate a malfunction, proceed as follows:
1. Clearly define the problem or symptom and when it
occurs.
2. Locate the problem in the Troubleshooting table.
3. Review all possible causes, then one at a time work
through the list of corrections until the problem is solved.
If maintenance procedures are not followed correctly,
injuries and/or property damage could result.
PROBLEM CAUSE CORRECTION
With the switch in • Open circuit • Check to see if unit is plugged in
the ON position,
fryer is completely • Check breaker or fuse at supply box
inoperative
• Check power switch per Power Switch
Section; replace if defective
• Check voltage at wall receptacle
• Check cord and plug
Shortening will not • Faulty contactor • Check contactor per Heating Contactors
heat but lights are on (elec. model) Section
• Faulty gas control • Check gas control valve per Gas Control
valve (gas model) Valve Assembly Section
• Faulty temperature • Check temperature probe per Temperature
probe Probe Replacement Section; “E6”
• Faulty high limit • Check high limit per the appropriate High
Temperature Limit Control Section; “E10”
• Faulty drain switch • Check drain switch per Drain Microswitch
Section; “E15"
1-2 1003