Model OFE/OFG/OEA/OGA-341, 342
1-2. TROUBLESHOOTING
(Continued)
PROBLEM CAUSE CORRECTION
Shortening will not • Drain valve clogged • Open valve, force cleaning brush through
drain from frypot with crumbs drain
• Drain valve will not • Replace cotter pins in valve coupling
open by turning
handle
Filter motor runs • Pump clogged • Remove pump cover and clean
but pumps shortening
slowly • Filter line connection • Tighten all filter line connections
loose
• Solidified shortening • Clear all filter lines of solidified shortening
in lines
Filter switch on, • Defective switch • Check/replace switch per Filter Switch
motor does not run Section
• Defective motor • Check/replace motor
• Motor thermal • Reset thermal switch on filter motor
protector tripped
Motor hums but • Clogged lines or • Remove and clean pump and lines
will not pump pump
• Replace pump seal, rotor and rollers
1-4 1003