Henny Penny OFE/OFG-342 Fryer User Manual


 
Model OFE/OFG/OEA/OGA-341, 342
1-2. TROUBLESHOOTING
(Continued)
PROBLEM CAUSE CORRECTION
Shortening will not Drain valve clogged Open valve, force cleaning brush through
drain from frypot with crumbs drain
Drain valve will not Replace cotter pins in valve coupling
open by turning
handle
Filter motor runs Pump clogged Remove pump cover and clean
but pumps shortening
slowly Filter line connection Tighten all filter line connections
loose
Solidified shortening Clear all filter lines of solidified shortening
in lines
Filter switch on, Defective switch Check/replace switch per Filter Switch
motor does not run Section
Defective motor Check/replace motor
Motor thermal Reset thermal switch on filter motor
protector tripped
Motor hums but Clogged lines or Remove and clean pump and lines
will not pump pump
Replace pump seal, rotor and rollers
1-4 1003