Hill Phoenix 05DMA Refrigerator User Manual


 
11
CONTROL SETTINGS
Manual Defrost
Button
Enter
Button
Up
Button
Down
Button
Fan
Status
LED
Compressor
Status
LED
Defrost
Status
LED
Factory Settings
Parameter Description
Setpoint
HY Hysteresis (differential) [1 to 9
o
F/
o
C]
LL Setpoint Low Limit [67
o
F (55
o
C) to HL]
HL Setpoint High Limit [LL to 99
o
F/
o
C]
CC Anti-Short Cycling Timer [0 to 9 min.]
Co Deep Freeze Cycle Time [0 to 99 min.]
AH High Temperature Alarm Value (degrees above setpoint) [0 to 55
o
F/
o
C]
AL Low Temperature Alarm Value (degrees below setpoint) [-50 to 0
o
F/
o
C]
Ad Alarm Differential [1 to 9
o
F/
o
C]
At Alarm Time Delay [0 to 99 min.]
dF Defrost Type (0-electrical; 1-hot gas)
dE Defrost End Mode (0-timed defrost; 1-temperature terminated defrost)
dt Defrost Termination Temperature [32
o
F to 68
o
F (0
o
C to 20
o
C)]
di Defrost Interval [0 to 99 hours]
dd Maximum Defrost Duration [1 to 99 min.]
dC Dripping Time After Defrost [0 to 99 min.]
dU Initial Defrost Interval (time before first defrost after startup) [0 to 99 min.]
dP Defrost Display (0-displays last value before defrost; 1-displays setpoint)
dr Display Delay After Defrost [1 to 99 min.
iF Digital Input Type (0-no digital input;
1-if digital input open, compres. off w/alarm on:
2-if digital input open, alarm on (contacts closed);
3-if digital input open, fan off w/alarm on)
id Digital Input Time Delay [0 to 99 sec.]
FF Fan Function (0-fan runs parallel with compressor; 1-fan on)
Fd Fan Start-Up Delay (after defrost) [0 to 99 min.]
Fr Fan Start-Up Temp. [-22
o
F to 41
o
F/-30
o
C to 5
o
C]
SF Sensor Failure Operation (0-compressor off; 1-compressor on;
2-compressor on/off based on last 4 cycles)
So Temperature Sensor Offset [-20
o
to 20
o
F/
o
C]
Un Units Used (0-
o
C; 1-
o
F)
PU Display Refresh Rate [1 to 99 sec.]
Factory Control Settings
O5DMA
38
2
-10
73
0
0
20
-10
5
3
0
1
44
6
42
0
99
0
20
0
0
1
5
40
1
0
1
1