Hobart HCE20H ML-126577 Convection Oven User Manual


 
32
TROUBLESHOOTING
Four lights (above) on the control panel indicate oven operation is not possible. If the Water Supply
valve is off and the steam generator does not have water, the Water Supply trouble indicator will light
and the buzzer will sound for one minute. The Water Supply trouble indicator light will remain lit until
the error is eliminated. Make sure the manual water valve is open. If the water valve was closed:
Switch the oven off; open the valve; and restart the oven. If the the Water Supply trouble indicator was
lit and the water valve was open, call Service. The other three lights on the control panel indicate oven
operation is not possible. Do not attempt to restart the oven. Switch the oven off and call Service.
NOTE: The oven can be used in Convection H
OT AIR Mode when the Water Supply trouble indicator
is lit.
Other error displays include [ 888C ] or [ 888F ] in the time display or [ 999C ] in the temperature display
while the probe is in use. These displays indicate that one of the temperature sensors is faulty: Call
Service.
If [ 00 ] is displayed in the time display during probe temperature cooking, the Temperature Probe is
faulty: Call Service.
If a prolonged power failure or an oven error occurs when food is located in the oven, the door may be
opened manually. 1) Switch the oven off. 2) Pull the door handle firmly towards you while firmly
pressing against the front of the oven with your other hand. This procedure is not used during normal
operation. If the electric door opener fails to operate, call Service.
If the appliance cannot be started and the temperature display blinks, make sure the door is properly
closed.
SERVICE ADJUSTMENTS
Buzzer loudness can be adjusted by your service technician.
SERVICE
Contact your local Hobart-authorized service office for any repairs or adjustments needed on this
equipment.
FORM 34039 (7-99) PRINTED IN U.S.A.