MAINTENANCE
WARNING: THE OVEN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING AND
SERVICING THE OVEN.
WARNING: DISCONNECT THE ELECTRICAL SUPPLY BEFORE PERFORMING ANY MAINTENANCE ON
THE OVEN.
Do not remove the oven covers or attempt to open the control cabinet. Doing so will void the warranty. There
are no user serviceable parts inside.
INSPECTING THE OVEN
At least once each day, when the oven is cool, visually inspect the inside of the oven. Make sure both lamp
shields are in place, clean, and unbroken. Make sure there are no obvious signs of damaged, worn, or broken
parts.
FUSES
There are two replaceable fuses located on the back of the oven (Fig. 6). Replace these fuses only with Class
CC 3 Amp Fuses.
CIRCUIT PROTECTORS
There are two resettable circuit protectors located on the back of the oven (Fig. 6). A tripped protector is indicated
by the reset button sticking out. To reset the protector, press the button.
LAMP REPLACEMENT
All lamps MUST be replaced by your local Hobart service representative.
Fig. 6
OVEN REAR
Blower
Fuses
Circuit
Protectors
#1
#2