Hobart HFB12 ML-114909 Oven User Manual


 
– 4 –
There must be a 3" (76 mm) clearance on each side of the oven. The area behind the oven around the blower
must be kept clear of obstructions and allow for free air circulation.
If your oven is equipped with the power cord and plug, ensure that the cord can be plugged into the appropriate
outlet.
INSTALLATION CODES AND STANDARDS
The HFB12
Flash
Bake oven must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. Canadian Electrical Code, Part 2, CSA Standard C22.1 (latest edition). Copies may be obtained from The
Canadian Standard Association, 178 Rexdale Blvd., Rexdale, Ontario, Canada M9W 1R3.
ASSEMBLY
Install the upper lamp shield into the oven cavity. Be sure the shield is pushed all the way back and is lying flat
in the channels. Refer to REMOVING AND INSTALLING THE TOP LAMP SHIELD in this manual.
Place the grill on the rollers.
EXHAUST DUCT INSTALLATION
A length of flexible exhaust duct may be attached to the oven to vent hot air out of the cooking area. Attach the
duct to the blower assembly (Fig. 1).
Fig. 1
Fan
Flexible Duct
(By Others)
OVEN REAR
Electrical
Junction Box
or
Power Cord Assembly
(If Applicable)
Duct Clamp
(By Others)
Blower
PL-52643