LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (Non-Filter Ready)
CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted
shortening.
1. Turn the thermostat OFF. The thermostat is located behind the door (Fig. 4).
PL-40677-1
Drain
Valve
Gas Control
Valve Knob
Thermostat
Knob
Non-Filter Ready
Fig. 4
2. Push the gas control valve knob and turn to OFF (Fig. 5). Wait 5 minutes for unburned gas to vent.
3. Push and turn gas control valve on to the "I" in PILOT (Fig. 5).
4. While still holding the knob in, light the pilot with a lit taper. Continue to depress the knob until pilot
remains lit when knob is released.
If the pilot does not remain lit, repeat steps 2 through 4.
5. Depress and turn gas control knob to ON (Fig. 5).
6. If gas supply is interrupted, repeat steps 1 through 5.
Fig. 5
TURNING THE FRYER ON (Non-Filter Ready)
To turn the fryer on, set the thermostat knob to the desired temperature. After the set temperature has
been reached, the gas control shuts off the gas flow to the burners. The pilot remains lit. The burners
will cycle on and off, maintaining the set temperature.