Hobart HGC20, HGC20, ML-114573, ML-114575 Convection Oven User Manual


 
– 6 –
LEVELING
Once the oven is in its permanent position, place a carpenter's level on the oven rack. If the oven is
installed on legs, turn the adjustable feet in or out to level oven front-to-back and side-to-side. If the
oven is installed on casters, loosen set screws and turn casters in or out to level oven front-to-back and
side-to-side. Retighten set screws after leveling.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE
PROVIDED WITH A THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG
BE CONNECTED INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. IF THE
RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO
NOT REMOVE THE GROUNDING PRONG FROM THIS PLUG.
The 120 volt models are equipped with a cord and plug.
Refer to electrical wiring diagram located inside the right side panel; remove control panel for access.
Do not turn the power supply on until after the gas connections have been made and checked for leaks.
Minimum Circuit Ampacity
Maximum Protective Device
MODEL Volts Hertz Phase AMPS
120 60 1 15
HGC20 200 - 240 50 1 15
200 - 240 60 1 15
HGC20D
120 60 1 15
200 - 240 50 / 60 1 15
ELECTRICAL DATA
Complied in accordance with the National Electrical Code, NFPA-70 (latest edition).