Hobart HGC85F ML-126963 Fryer User Manual


 
– 5 –
ASSEMBLY
When installed, the fryer must be restrained to prevent tipping to avoid the splashing of hot liquid. The
means of restraint may be the manner of installation, such as connection to a battery of appliances or
installing the fryer in an alcove, or by separate means, such as adequate ties.
Fryers Mounted on Legs (Non-Batteried Fryers)
Fryers serviced from the rear must have a minimum clearance of 18" (46 cm) from the wall when
mounted on legs.
1. Position fryer in an open space near the final installation area.
2. Tilt fryer on its side. Be careful not to scratch the finish.
3. Thread legs into mounting holes provided on bottom of fryer, then tighten.
4. Carefully raise fryer to its normal position.
Fryers Mounted on Casters
Fryers mounted on casters must use a flexible connector (not supplied by Hobart) that complies with
the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 • CSA 6.16 and a quick-
disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas
Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate means must be provided to limit movement of the
appliance without depending on the connector and the quick-disconnect device or its associated piping
to limit appliance movement. Attach the restraining device at the rear of the fryer as shown in Fig. 3.
If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect
this restraint prior to turning the gas supply on and returning the fryer to its installation position.
INSTALLATION CODES AND STANDARDS
Hobart fryers must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1 (latest edition). Copies may be obtained from The American
Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.
3. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CSA B149.1 Natural Gas and Propane Installation Code.
3. CSA C22.2 Canadian Electrical Code.
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,