Gas Valve Extension Arm - Used to ignite and operate the pilot.
LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (HGFD & HGFC SERIES)
CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted
shortening.
1. Push the gas valve extension arm in and turn arm to OFF. Wait 5
minutes for unburned gas to vent. (Fig. 8)
2. Push gas valve extension arm in.
3. While still depressing the arm, light the pilot with a lit taper. Continue
with steps 2 through 4 until pilot remains lit when the extension arm
is released.
4. Turn gas valve extension arm to ON.
5. Repeat steps 1 through 4 if gas supply is interrupted.
SHUTDOWN INSTRUCTIONS WITH MANUAL PILOT IGNITION (HGFD & HGFC SERIES)
1. Turn power switch to OFF.
2. Turn the extension arm to OFF.
EXTENDED SHUTDOWN FOR MANUAL PILOT IGNITION FRYER (HGFD & HGFC SERIES)
1. Turn the thermostat knob to OFF.
2. Turn the gas valve extension arm to OFF.
3. Turn the main gas shutoff valve off.