Hobart ML - 104481 Mixer User Manual


 
– 11 –
Attachments
To install an attachment, loosen the attachment hub thumb screw and remove the plug. Insert the
attachment into the attachment hub, making certain that the square shank of the attachment is in the
square driver of the mixer. Secure the attachment by tightening the thumb screw.
Move the gear shift lever to the desired speed. With the bowl support all the way up and the wire cage
in the front-center position, start the mixer to operate the attachment.
The meat and food chopper attachment should be operated in second or third speed. If material in the
cylinder stalls the mixer, push the STOP button at once. DO NOT attempt to restart the mixer in a lower
speed — remove the adjusting ring, knife, plate, and worm and clear any obstruction. THIS ATTACHMENT
MUST NOT BE USED TO CHOP BREAD CRUMBS.
NOTE: Attachment hub should not be used while mixing.
Bowl Scraper Attachment
The Mixer Bowl Scraper Attachment (when ordered) is provided with a separate instruction manual
covering its installation, operation, use and care.
CLEANING
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT BEFORE BEGINNING ANY
CLEANING PROCEDURE.
A flat scraper and a brush are furnished to aid in cleaning bowls and agitators.
The mixer should be thoroughly cleaned daily. DO NOT use a hose to clean the mixer — it should be
washed with a clean damp cloth. The base allows ample room for cleaning under the mixer. The apron
may be removed by loosening the thumb screws. Behind this apron is an access cover which may be
removed for cleaning.
The Drip Cup-Splash Guard (which is secured by three screws) should be removed periodically and wiped
clean.
For cleaning the Bowl Guard (including both Wire Cage Assembly and Splash Guard), refer to page 10.
MAINTENANCE
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT BEFORE
BEGINNING ANY MAINTENANCE PROCEDURE.
LUBRICATION
Bowl Clamps
The bowl clamp area of the bowl support should be lubricated twice a year. Lightly coat with Lubriplate
630AA (supplied).