Hobart ML - 104481 Mixer User Manual


 
– 6 –
PROGRAMMABLE TIMER CONTROLLER (when equipped)
At Idle, the timer display
[ – – : – – ]
shows that no time has been set (Fig. 4).
Fig. 4
Timer Keys Programming Function (if the mixer is not mixing).
P1 Contains up to four preset times. Displays each preset time sequentially.
P2 Contains up to four additional preset times. Displays each preset time sequentially.
Knob Changes the time as indicated by the display.
Save Replaces the preset time with the indicated time.
Clear Returns to Idle from a programming function.
For Continuous Mixing . . .
START and STOP buttons control mixing operation.
Beginning from the Idle display
[ – – : – – ]
, press START to begin mixing. The M/C
indicator will be lit, and the total mixing time will be indicated (minutes and seconds).
Press STOP when mixing is done; the M/C indicator light goes off; and the Idle display
[––:– ]
returns.
Using the Dial Timer to set the Mixing Time . . .
Beginning from the Idle display
[ – – : – – ]
, turn the KNOB to set the mixing time. The
M/C indicator will be lit.
START and STOP buttons control mixing operation.
Press START to begin mixing: The timer will countdown from the set time to
[ 00 : 00 ].
If STOP is pressed, both mixing and timer countdown will be interrupted. After
pressing STOP . . . Press START to resume both mixing and timer countdown; or,
press CLEAR to return to the Idle display.
When the timer reaches [ 00 : 00 ] the mixer stops; M/C indicator goes off; a beep tone
sounds for two seconds; and the Idle display
[ – – : – – ]
returns.
START
STOP
TIME
SAVE
Clear Key
CLEAR
Time Display
Stop Button
Start Button
Save Key
Knob
TIMER CONTROLLER
1 2 3 4
P1
P2
M/C
STOP MIXER
BEFORE
CHANGING SPEEDS
3
1
2
P2 Key
P1 Key
M/C Indicator
Gear Shift Lever