Honeywell PGF3 Wok User Manual


 
-- 4 --
462 06 1211 00
3/17/06
Manifold/Orifice Measurement
Measure 1
3
/16 from face of orifice
to back edge of manifold pipe.
Figure 4
Changing Pilot Burner Orifice
(Required for Converting from Propane Gas
to Natural Gas) (All models except PGF3,
PGX3, and PDX3).
1. Disconnect the pilot supply line from the pilot burner.
2. Remove pilot orifice from pilot burner. Replace with natural
gas orifice stamped which is provided in kits (Figure 5)
3.. Reconnect the pilot tubing securely to the pilot burner.
4. Verify proper relationship of pilot burner assembly per fig-
ure 6, prior to completing the conversion.
Changing Pilot Orifice
Pilot
Orifice
Figure 5
Figure 6 Burner Pilot Assembly
Gas Valve Conversion (Required for Converting
from Propane Gas to Natural Gas)
Conversion of Honeywell VR8200, SV9500, SV9501 and
VR8204M Gas Valves using Natural Gas Conversion Kit #
396222.
1. Remove the regulator cap screw and pressure regulator ad-
justing screw. (See Figure 10)
2. Remove the existing regulator spring from the regulator
housing.
3. Insert the replacement spring (stainless steel) contained in
this kit into regulator housing.
Typical Gas Valve Honeywell
SV9500
WARNING
Explosion Hazard.
Serious injory or death
can result.
Read instructions before
operating valve.
Never
use tools to
operate valve
.
Do not
disassemble valve. call a
qualified service technician
if the appliance does not
function properly.
Honeywell
CONTROL
IGNITER
OFF
ON
25-50-06
INLET
OUTLET
Pilot Adjustment
Pilot
Outlet
Wiring
Terminals
Outlet Pressure Tap
Connect manometer here to
check outlet pressure. Must be
adjusted per Table 1.
Inlet Pressure
Tap (Hidden)
Figure 7