Honeywell PGF3 Wok User Manual


 
-- 7 --
462 06 1211 00
3/17/06
Pilot Burner Flame Check (All models
except PGF3, PGX3, and PDX3)
Adjust flames so they surround
3
/
8
(9 mm) to
1
/
2
(13 mm) of the
sensor tip (See Figure 11).
1. Remove the cap from the pilot adjusting screw (See Fig-
ures7&8).
2. Turn pilot adjusting screw counterclockwise to increase,
clockwise to decrease.
3. Replace the cap on the pilot adjusting screw.
Pilot Burner (HSP)
10 -- 11 -- 65
Sensor Tip
Proper Flame
Adjustment
Hot Surface
Igniter
Figure 11
Main Burner Flame Check
Check for the following:
D Stable and blue flames (See Figure 12). Dust may cause
orange tips or wisps of yellow, but flames MUST NOT have
solid, yellow tips.
D Flames extending directly from burner into heat exchanger.
D Flames DO NOT touch sides of heat exchanger
Main Burner
BLUE FLAME
25--00--07a