- 3 -
WATER INLET CONNECTIONS
A standard 120-volt power cord provides the
electrical connection. The unit is designed to
operate on a separate 15-amp circuit.
Inlet Water Line Connection
• 1
st
production units had a 3/4" BSP
connection directly to the inlet water
valve. (DO not connect with 3/4" FIP)
• Fitting (4A3207-01) and gasket
413854-01 were used from May
through July production. (Through
August on the AM-100BAE and AM-
150 BAF)
• Fitting (4A3240-01) and gasket
413854-01 were added in August 03
on the AM-50BAE and September 03
on the AM-100BAE and AM-
150BAF.
If no fitting is included, order either fitting
/gasket above or use 3/4" hose type fitting to
make this connection.
A minimum 3/8” water line is required for
proper operation.
Drain line connection
The drain connection for the AM-50 was
5/8” I.D. hose until April of 2004 and was
located on the left rear of the unit. A
standard 3/4” male insert fitting can be used
to connect this drain. From May 2004 the
drain fitting is 1/2” FPT. A minimum 1/2”
I.D. vented drain is required when making
this connection.
The drain for the AM-100 and AM-150 is a
3/4” MPT.
Since the unit will likely be enclosed, it is
recommended to use flexible, supply and
drain connections. This will allow easy
removal if service is necessary.
DRAIN
CONNECTIONS
4A32
40
-
01
1/2” FPT
4A3207-01
3/8” Male flare
(AM-50 through April
2004)
(AM-100 & AM-150)
AM-50 from May 2004
1/2” FPT
3/4” MPT
5/8” I.D. rubber hose