Hoshizaki DCM-750BAH Ice Maker User Manual


 
3
D. Sequence of Electrical Circuit – Dispensing
1. Continuous Dispense
Agitating motor energizes for .6 seconds for every  seconds of accumulative dispense
time. Maximum dispense time per dispense switch activation is 60 seconds. After
60 seconds, the dispense switch must be disengaged and engaged again.
BK BLACK O ORANGE W/BK WHITE/BLACK
BR BROWN P PINK W/BR WHITE/BROWN
BU BLUE R RED W/BU WHITE/BLUE
DBU DARK BLUE V VIOLET W/O WHITE/ORANGE
GY GRAY W WHITE W/R WHITE/RED
LBU LIGHT BLUE Y YELLOW
WIRE COLOR CODE
DCM-750BAH-OS,
DCM-750BWH-OS
DCM-750BAH,