Hoshizaki DCM-750BAH Ice Maker User Manual


 
35
2. DCM-750BWH(-OS)
Note:
. The data without *marks should be used for reference only.
. We reserve the right to make changes in specications and design without prior
notice.
APPROXIMATE Ambient Water Temp. (F)
ICE PRODUCTION Temp. (F)
PER 24 HR. 70 * 744 337
719 326 708 321
80 696 316 684 310 673 305
90 662 300 * 654 297 640 291
lbs./day ( l/day) 100 630 286 620 281 * 573 260
APPROXIMATE ELECTRIC 70 * 1410 -- 1383 -- 1382 --
CONSUMPTION 80 1410 -- 1383 -- 1382 --
90 1410 -- * 1383 -- 1382 --
watts 100 1410 -- 1383 -- * 1382 --
APPROXIMATE WATER 70 * 139 0.63 160 0.73 225 1.02
CONSUMPTION PER 24 HR. 80 137 0.62 160 0.73 228 1.04
(TOTAL) 90 135 0.62 * 160 0.73 232 1.05
gal. / day (kl/day) 100 134 0.61 160 0.73 * 242 1.10
EVAPORATOR OUTLET TEMP. 70 * 19 -7 19 -7 19 -7
°F (°C) 80 19 -7 19 -7 19 -7
90 19 -7 * 19 -7 19 -7
100 19 -7 19 -7 * 19 -7
HEAD PRESSURE 70 * 265 18.6 267 18.8 266 18.7
80 265 18.6 267 18.8 266 18.7
90 265 18.6 * 267 18.8 266 18.7
PSIG (kg/cm
2
G) 100 265 18.6 267 18.8 * 266 18.7
SUCTION PRESSURE 70 * 50 3.5 50 3.5 51 3.6
PSIG (kg/cm
2
G) 80 50 3.5 50 3.5 51 3.6
90 50 3.5 * 50 3.5 51 3.6
100 50 3.5 50 3.5 * 51 3.6
50 70 90
WATER FLOW FOR CONDENSER 21 gal/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM CONDENSER
PRESSURE DROP OF COOLING WATER LINE
HEAT OF REJECTION FROM COMPRESSOR
7945 BTU/h (AT 90°F /WT 70°F)
Less than 7 PSIG
1469 BTU/h (AT 90°F /WT 70°F)