H. Startup
WARNING
1. All parts are factory-adjusted. Improper adjustments may adversely affect
safety, performance, component life, and warranty coverage.
2. If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
3. At startup, conrm that all internal and external connections are free of leaks.
1) Open the water supply line shut-off valve(s).
2)Movethecontrolswitchtothe"OFF"position.SeeFig.7.
3)Removethefrontpanel,thenmovethepowerswitchtothe"ON"position.Replacethe
front panel in its correct position, then turn on the power supply.
Note: This unit will not run if the safety switch is not engaged.
4)Movethecontrolswitchtothe"ICE"positiontostarttheautomaticicemakingprocess.
5) Once the unit starts to produce ice, allow it to run for another 30 minutes.
6)Movethecontrolswitchtothe"OFF"position,pausemomentarily,thenmovetothe
"DRAIN"position.Allowthewatersystemtodrainfor5minutes.
Note:a)Amomentarypauseinthe"OFF"positionisnecessarytode-energizethe
controlboardwhenmovingthecontrolswitchbetween"ICE"and"DRAIN."
Otherwise there is a delay of several minutes before the new selection takes
effect.
b)Ifthecontrolswitchisleftinthe"DRAIN"positionfor10minutesormore,a
2-beep alarm sounds every 5 seconds. Move the control switch out of the
"DRAIN"positiontoclearthealarm.
7)Movethedispensemodeswitchtothe"CONTINUOUS"position,thendispenseallof
the ice from the storage bin.
Note: Ice dispenses continuously for a maximum of 60 seconds per activation.
Fig. 7
Power Switch
Safety Switch
Actuator Paddle
Storage Bin Cover
Control Box Cover
CONTROL
DISPENSE MODE
4A1038-014
ICE
OFF
DRAIN
PORTION
CONTINUOUS