Hoshizaki FD-1001MWH(-C) Ice Maker User Manual


 
4
7) Connect the refrigerant lines to the appropriate ttings on the rack system rst (if not
already brazed on), then at the icemaker.
If the couplings to the rack system are not Parker quick connect couplings, follow the
coupling manufacturer's instructions. Make a proper Parker quick connect coupling
connection as follows:
a. Remove the protective covers from the male tting and female coupling.
b. Apply Polyol Ester (POE) refrigerant oil to the entire male tting, including threads,
o-ring, and diaphragm, before making the connection. See Fig. 1.
CAUTION
Do not use thread sealant on the ttings. Use POE refrigerant oil only.
c. Make sure the male tting and female coupling are properly aligned, then start the
connection by hand to ensure that it is not cross threaded.
d. Place a backup wrench on the back of the female coupling, then tighten the
connection with a wrench until it is tight. At this point, the nut has covered most of
the threads on the male tting. CAUTION! Failure to use a backup wrench may
result in damage to the line set and possible refrigerant leaks.
e. Mark a reference line on the female coupling and the unit panel. Using a backup
wrench on the back of the female coupling, tighten the six-sided nut of the female
coupling an additional 1/6 turn. See Fig. 13.
8) Open the rack system service valves.
Female Coupling
(Charging Ports)
3/8" OD Suction Line
(Insulated)
Rack System-Threaded Connection
1/4" OD Liquid Line
(Insulated)
Icemaker
Male Fitting
Service Loop
Fig. 11
Female Threaded Coupling
Rack System-Braze Connection
Male Threaded Fitting
3/8" OD Suction Line
(Insulated)
1/4" OD Liquid Line
(Insulated)
3/8" OD Suction Line
(Insulated)
1/4" OD Liquid Line
(Insulated)
Braze Conneciton