26
2. KM-1601MRH with URC-22F
70/21 1493 677 1471 667 1410 640
80/27 1476 670 1441 654 1364 619
90/32 1471 667 1417 643 1346 610
lbs./day kg./da
y
100/38 1449 657 1400 635 1280 581
70/21
80/27
90/32
watts 100/38
70/21 521 1.97
446 1.69 396 1.50
80/27 464 1.75 346 1.31 327 1.24
90/32 446 1.69 264 1.00 230 0.87
gal./day m
3
/day
100/38 355 1.34 256 0.97 200 0.76
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 205 14.4
218 15.3 233 16.4
80/27 215 15.1 236 16.6 249 17.5
90/32 218 15.3 250 17.6 265 18.6
PSIG kg/cm
2
G
100/38 220 15.5 254 17.8 279 19.6
70/21 38 2.7 40 2.8 42 3.0
80/27 39 2.8 42 2.9 44 3.1
90/32 40 2.8 43 3.1 46 3.2
PSIG kg/cm
2
G
100/38 40 2.8 44 3.1 48 3.4
CONDENSER VOLUME 214 CU. IN.
23
24
25
2.9
5.4
3.8
4.7
3.8
3.0
4.8
22
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10 70/21 90/32
28
30
2642
2634
2692
2740
2752
2590
2623
2634
27
24
24
26
2687
2741
2792
2840
25
27
2.2
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
4.2
3.5
4.7 2.6
TOTAL HEAT OF REJECTION FROM CONDENSER 27,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR 3,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
ENG.F-011.1.0205
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specications and design without prior
notice.