Hoshizaki KM-1900SAH/3 Ice Maker User Manual


 
27
H. Water Supply and Drain Connections
See Fig. 17, 18, and 19
WARNING
1. Water supply and drain connections must be installed in accordance with
applicable national, state, and local regulations.
2. Normal operating water temperature should be within 45°F to 90°F (7°C
to 32°C). Operation of the icemaker, for extended periods, outside of this
normal temperature range may affect icemaker performance.
3. To prevent damage to equipment, do not operate the icemaker when the
water supply is off, or if the pressure is below 10 PSIG. Do not run the
icemaker until the proper water pressure is reached.
•Aplumbingpermitandservicesofalicensedplumbermayberequiredinsomeareas.
•Externallters,strainers,orsoftenersmayberequireddependingonwaterquality.Contact
your local Hoshizaki distributor for recommendations.
•Watersupplypressureshouldbeaminimumof10PSIGandamaximumof113PSIG.If
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
•Theicemakerandcondensationdrainline(s),storagebindrainline,andwater-cooled
condenser drain line (if applicable) must be run separately.
•Drainlinesmusthave1/4"fallperfoot(2cmper1m)onhorizontalrunstogetagood
ow. A vented tee connection is also required for proper ow.
•Drainlinesshouldnotbepipeddirectlytothesewersystem.Anairgapofaminimumof
2vertical inches (5 cm) should be between the end of the drain pipes from the icemaker
and condensation drain, storage bin, and water-cooled condenser (if applicable) and the
oor drain.