Hoshizaki KM-260BAH Ice Maker User Manual


 
20
S2 Dip Switch Setting
Anti-Slush Control
No. 5 No. 6
OFF OFF Activated (Ver. 1.0)
ON OFF Activated (Ver. 2.0)
OFF ON Deactivated
ON ON Deactivated
Control Board P01771-02
j) Harvest Promotion Control (S2 dip switch 2) [Program Ver. 3.2]
Do not adjust. This must be left in the factory default position or the unit will not operate
properly.
When activated, this control promotes harvest of ice on the evaporator that is hard to
remove. If the harvest cycle exceeds 6 minutes, the pump motor starts to operate for a
maximum of 3 minutes.
S2 Dip Switch Setting
Harvest Promotion
Control
No. 2
OFF Activated
ON Deactivated
k) Re ll Counter (S2 dip switch 3) [Program Ver. 3.2]
Do not adjust. This must be left in the factory default position or the unit will not operate
properly. The KM-201BAH/BWH and KM-260BAH/BWH do not re ll.
l) Harvest Completion Detection Control (S2 dip switch 4) [Program Ver. 3.2]
Do not adjust. This must be left in the factory default position or the unit will not operate
properly.
It is deactivated on the KM-201BAH/BWH and KM-260BAH/BWH.
When activated, this control determines whether ice remains on the evaporator at the
end of a harvest cycle and at the beginning of a freeze cycle. If ice drops and activates
the bin control switch in the last 10 seconds of a harvest cycle, the control determines
that ice still remains on the evaporator and extends the harvest cycle for 30 seconds.
If the bin control switch is activated at the beginning of a freeze cycle, the control
determines that ice still remains on the evaporator and starts a harvest cycle after the
minimum freeze cycle time has passed.
S2 Dip Switch Setting
Harvest Completion
Detection Control
No. 4
OFF Deactivated
ON Activated