6. KM-600MAH
AC SUPPLY VOLTAGE 115-120/60/1
AMPERAGE 12.0 A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *592 (269) 566 (257) 516 (234)
Reference without *marks 80 572 (260) 532 (241) 474 (215)
90 566 (257) *503 (228) 447 (203)
100 551 (250) 490 (222) 396 (180)
SHAPE OF ICE Crescent Cube
ICE PRODUCTION PER CYCLE 14.3 lbs. (6.5 kg) 720 pcs.
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1190(5.7) 1040(4.2)
WATER gal./24HR (gal./100 lbs.) 99(19.7) 259(43.7)
CEC/CEE TIER LEVEL 2
ENERGY STAR YES
EXTERIOR DIMENSIONS (WxDxH) 22" x 27-3/8" x 37-7/16" (560 x 695 x 950 mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 169 lbs. (77 kg), Shipping 200 lbs. (91 kg)
CONNECTIONS - ELECTRIC Permanent-Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT
3/8" OD Tube
CUBE CONTROL SYSTEM Float Switch
HARVESTING CONTROL SYSTEM Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL Timer Controlled. Overflow Pipe
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostatic or Mechanical Bin Control
COMPRESSOR Hermetic, Model RST55C1E-CAA
CONDENSER Air-Cooled, Fin and Tube Type
EVAPORATOR Vertical Type, Stainless Steel and Copper
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, 1 lb. 11 oz. (765g)
DESIGN PRESSURE High 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-Out (Internal)
COMPRESSOR PROTECTION Auto-Reset Overload Protector (Internal)
REFRIGERANT CIRCUIT PROTECTION Auto-Reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch
ACCESSORIES -SUPPLIED N/A
-REQUIRED Ice Storage Bin
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 -100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
ENG.F-011.1.0205
Note: We reserve the right to make changes in specications and design without prior