II. Sequence of Operation and Service Diagnosis
A. Sequence of Operation Flow Chart
1. "E" and "G" Control Board without Harvest Pump Timer Operation
Components Energized when the Control Switch is in the "WASH" Position
The "WASH" position on the control switch is used when cleaning and sanitizing the icemaker. When in the "WASH" position,
power is supplied to the pump motor. With the cleaning valve closed, the cleaner and sanitizer ow over the outside of the
evaporator plate assembly. With the cleaning valve open, the cleaner and sanitizer ow over both the outside and the inside
of the evaporator plate assembly.
Note: Close the cleaning valve after cleaning and sanitizing are complete, otherwise the icemaker will not restart when the
control switch is placed in the "ICE" position.
Legend:
Comp–compressor
FM–fan motor
FMR–fan motor-remote
FS–oat switch
HGV–hot gas valve
LLV–liquid line valve
PM–pump motor
WV–inlet water valve
• Maximum inlet water valve time: 6 min.
• Maximum harvest time: 20 min.
FS check
1 to 3-min. harvest
timer in control
(S4 dip switch 1 & 2)
"E" and "G" Control Board Without Harvest Pump Timer Operation Flow Chart
1. 1-Minute
Fill Cycle
Cycle
Steps
2. Harvest Cycle
Thermistor in
control
3. Freeze Cycle
• Minimum freeze time: 5 min.
• Maximum freeze time: freeze
timer setting
(S4 dip switch 9 & 10)
FS in control
4. Pump-Out Cycle
• Factory set for every
10th cycle
(except KM-515M_H)
(S4 dip switch 5 & 6)
• Pump motor stops for
2 sec., then reverses
for 10/20 sec. (S4 dip
switch 3 & 4)
WV energized
FS open
Comp energized
FMR energized
HGV energized
WV energized
Thermistor temperature
reaches 48°F (9°C) (3.9 kΩ
or less). Harvest timer starts
(1 to 3 min.).
FS open
Comp continues
FMR continues
FM energized
LLV energized
PM energized
HGV de-energized
WV de-energized
FS closed
Comp continues
FMR continues
HGV energized
WV energized (KM-320M_H S4 dip
switch 3 & 4)
PM de-energizes for 2 sec.,
then reverses for 10/20 sec.
FM de-energized
LLV de-energized
FS check
Startup
If FS is open, Comp stops and cycle returns to 1-min. ll.
5-min. minimum
freeze timer in
control
FS closed
FS opens or
freeze timer
terminates
Shutdown and Restart
See next page.