ELECTRICAL REQUIREMENTS
For your own safety, we recommend that your cooker is installed by a competent person
such as one who is registered with NICEIC (National Inspection Council for Electrical
Installation Contracting). The cooker should be installed in accordance with the latest
edition of the IEE Regulations.
Warning: This appliance must be earthed.
ELECTRICAL CONNECTIONS
The installer must check that the voltage shown at the rating plate corresponds with the
house electricity supply.
The cooker must be supplied via a suitable double pole isolating switch, having a contact
separation of at least 3mm in all poles placed in a readily accessible position adjacent to
the cooker.
If the cooker is to be wired into a connector unit, this may be positioned behind the cooker
providing the following requirements are met:
i) The connector unit must not project from the wall more than 25mm.
ii) The top of the connector must not be more than 130mm above floor level.
Remove the terminal cover at the rear base of the cooker. Pass the cable through the cable
clamp and connect to the appropriate terminals provided.
Allow sufficient cable for any future servicing.
Tighten the screws on the cable clamp and replace the cover.
Make main connections in the connector unit or cooker control unit.
This appliance conforms to B.S. EN 55014 regarding suppression of Radio and Television
reception interference.
A double Pole control switch having a minimum rating of 32 amps should be used to feed
the cooker using a suitably rated cable.
Where a hob is fitted adjacent to or over the cooker, a 45 amp Double Pole control switch
should be used to feed both units via separate suitably rated cables.
We recommend a minimum of 4mm
2
PVC insulated twin and earth cable conforming to
B.S. 6004 for connection of each appliance.
Where a hob is fitted above the cooker the cable connecting the hob to the cooker
control unit must be of 2.5mm
2
85
o
C heat resistant cable to BS6141 table 15
In all cases adhere to routing details (see fig. 5).
This appliance must not be installed over any other appliance that generates heat such as a
plinth heater
INSTALLATION
31
Note: Due to many different types of installation, a mains cable is not supplied with this
product. The installer will fit the correct type and length of cable.