Hotpoint H050E Cooktop User Manual


 
Installation
WARNING – THIS APPLIANCE MUST BE EARTHED.
Your cooker should be checked to ensure that the voltage corresponds with
your supply voltage, this is stated on the rating plate, which is situated on the
rear panel as shown on page 5. The cooker must be connected by a competent
person such as one registered with the National Inspection Council for Electrical
Installation Contracting (NICEIC) to a suitable double-pole control unit with a
minimum rating of 45A and a minimum contact clearance of 3mm, which should
be fitted adjacent to the cooker, in accordance with IEE regulations.
The power supply cable should conform to B.S.6004 with a conductor size of
6mm
2
minimum.
The control unit should be easily accessible in the event of an emergency.
This appliance conforms to EN55014
regarding suppression of radio and
television interference.
Access to the mains terminals is gained by removing the rear access cover.
The mains cable must pass through the cable clamp on rear panel and ensure that
the rear access cover is replaced after fitting the cable. Sufficient cable should
be used to allow the cooker to be pulled out for servicing.