Electrical Connection
This appliance conforms to the following EEC Directives:
Low Voltage Equipment
73/23/EEC
93/68/EEC
Electromagnetic Compatibility
89/336/EEC
93/68/EEC
Inner dimensions of the oven:
width cm.54
depth cm.38
height cm.33
Voltage and frequency of power supply:
230 V
50-60Hz
2400W
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption for Natural convection
heating mode:
Convection
Declared energy consumption for Forced convection
Class
heating mode: Fan assisted
Electric connection
Appliances with a three-pole power supply cable are
designed to operate with alternated current at the supply
frequency and voltage indicated on the data plate (at the
bottom of the oven dashboard). The earthing conductor
of the cable is the yellow-green conductor.
Connecting the power supply cable to the mains
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum
contact opening of 3 mm installed between the appliance
and the mains, suitable for the load indicated and
complying with current directives (the earthing wire must
not be interrupted by the circuit-breaker).
The power supply cable must be positioned so that it
does not exceed 50°C more than room temperature at
any point of its length.
Before making the connection check that:
- the limiter valve and the home system can support
the appliance load (see data plate);
- the power supply system has an efficient earthing
connection which complies with the provisions of
current regulations;
- the socket or omnipoar circuit-breaker is easily
accessible once the cooker has been installed.
NOTE: do not use reducers, adaptors or shunts as they
could cause overheating and burns.