Hotpoint SC88X Oven User Manual


 
16
Electrical connection
The electrical connection to the mains must be made on the
appliance. The power voltage and frequency are as
indicated on the rating plate.
WARNING: THIS APPLIANCE MUST BE EARTHED.
Mounting the power supply cable
To open the terminal board:
Using a screwdriver, press on the tabs situated on each
side of the terminal board cover.
Pull open the terminal board cover.
To mount the power supply cable, proceed as follows:
Unscrew the cable clamp screw and the contact screws.
Position the jumpers accordingly to the type of connection
you wish to make as per the diagrams below.
Note: The jumpers are factory set for a 230V single
phase connection.
Fasten the power supply cable in the corresponding
cable clamp and close the cover.
Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which is
long enough to allow you to take the oven out of its recess
in the event of maintenance operations (only use HAR - H
05 - RRF quality cables fitted with a plug conforming to the
regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even when
replacing the oven lamp.
Using the appliance without correct earthing is highly
dangerous.
IMPORTANT:
After connecting the appliance to the flexible cable, tighten
all the screws on the terminal board.
Electrical Connection
This appliance conforms to the following EEC Directives:
Low Voltage Equipment
73/23/EEC
93/68/EEC
Electromagnetic Compatibility
89/336/EEC
93/68/EEC
Inner dimensions of the oven:
width 43.5cm
depth 40.0cm
height 32.0cm
Inner volume of the oven: 56 litres
Voltage and frequency of power supply:
230-240V
50-60Hz
2250-2400W
Electrical Connections:
Voltage Frequency: 230 V-1+N 50Hz
Fuse Section: 32A 4mm
3
You can connect your oven to the system means of a
terminal board. Refer to above information for the minimal
cable sections and the calibration of the protective
elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
•••
LN
123 4 5
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption for Natural convection
heating mode: f Convection
Declared energy consumption for Forced convection Class
heating mode: g Ventilated