hussman IGSS-FMSS-0301 Range User Manual


 
Rev.0301
15
Specifications
FMSS Medium Temp
TEMPERATURE DISCHG. TYPE & FAN SIZE DEFROST
Max 115 V. ELECTRICAL CIRCUITS SELF CONTAINED
BTU AVG AIR T-STAT/ MAKE & FREQ. Low Pressure
REQ’D EVAP PROD DISC VELOC CUT IN EVAP. NUMBER & STD. Control &
PER FT. TMP TMP TMP @FPM SETTINGS COIL OF MOTORS DURATION FANS Warmers LIGHTS Settings H.P. VOLTS AMPACITY
4' Remote 450 18° 35°- 28° 100 Optional Forced 4
1
/2” Axial 45 min. .18 1.16 50# In 1/4 115 9.0
37° Air (1) (3) 30# Out
6' Remote 450 18° 35°- 28° 100 Optional Forced 4
1
/2” Axial 45 min. .36 1.16 50# In 1/3 115 10.9
37° Air (2) (3) 30# Out
8' Remote 450 18° 35°- 28° 100 Optional Forced 4
1
/2” Axial 45 min. .54 1.16 50# In 1/2 115 19.9
37° Air (3) (3) 30# Out
10' Remote 450 18° 35° - 28° 100 Optional Forced 4
1
/2” Axial 45 min. .54 1.16 50# In 3/4 208/ 8.7
37° Air (3) (3) 30# Out 240
12' Remote 450 18° 35°- 28° 100 Optional Forced 4
1
/2” Axial 45 min. .72 1.16 50# In 3/4 208/ 8.7
37° Air (4) (3) 30# Out 240
NOTES:These refrigerated merchandisers have been designed for use in stores where temperatures and humidity are maintained at or below 75°F and
55%RH. Stores are responsible for setting their cases approprately in conditions which vary from the above. The number of defrosts and/or the duration may
vary for cases displaying products for which they were not designed. Italicized data indicates optional equipment.
These case specs serve as a guideline for planning purposes and installation.Please consult the label on the back of the case to verify actual case
loads.