hussman RGSSFP Refrigerator User Manual


 
Rev.0008
9
Specifications
TEMPERATUREDISCHG. FAN SIZE DEFROST
115 V. ELECTRICAL CIRCUITS
SELF CONTAINED UNIT DATA / SEE CROSS REF.
BTU AVG AIR T-STAT/ TYPE & FREQ. SELF CONTAINED
REQ’D EVAP PRODDISC VELOC CUT IN OF NUMBER & E E FANS STD. RECEP- LOW PRESSURE
Length
PER FT. TMP TMP TMP @FPM SETTINGS COIL OF MOTORS DURATION (EPR) FANS WARMERS LIGHTS TACLE CONTROL & SETTINGS H.P. VOLTS AMPACITY
RGSSFP
4' Deli 650 18° 36° 28° 175 EPR Forced 7" x 20° 40 min. .33 .6 .3 .56 top only 15.0 35# Out 1/3 115 11.9
36° Air (1) (3) 1.12 top & one shelf 55# In
1.68 top & two shelves
Refrig. Rear storage 175 18° 36° 28° 125 EPR Forced 40 min. N/A .64 N/A N/A - - not offered
36° Air (3)
Refrigerated Dome 200 18° 36° 28° 250
6' Deli 650 18° 36° 28° 175 EPR Forced 7" x 20° 40 min. .66 1.2 .4 .56 top only 15.0 35# Out 1/2 115 18.1
36° Air (2) (3) 1.12 top & one shelf 55# In
1.68 top & two shelves
Refrig. Rear storage 175 18° 36° 28° 125 EPR Forced 40 min. N/A 1.28 N/A N/A - - - 3/4* 208/ 8.7
36° Air (3) 230
Refrigerated Dome 200 18° 36° 28° 250
8' Deli 650 18° 36° 28° 175 EPR Forced 7" x 20° 40 min. .66 1.2 .5 .56 top only 15.0 35# Out 3/4 208/ 8.7
36° Air (2) (3) 1.68 top & one shelf 55# In 230
2.8 top & two shelves
Refrig. Rear storage 175 18° 36° 28° 125 EPR Forced 40 min. N/A 1.28 N/A N/A - - - 1* 208/ 13
36° Air (3) 230
Refrigerated Dome 200 18° 36° 28° 250
12' Deli 650 18° 36° 28° 175 EPR Forced 7" x 20° 40 min. .99 1.8 .8 1.15 top only 15.0 35# Out 1 208/ 13.0
36° AIR (3) (3) 2.83 top & one shelf 55# In 230
4.51 top & two shelves
Refrig. Rear storage 175 18° 36° 28° 125 EPR Forced 40 min. N/A 1.28 N/A N/A - - - 1
1
/
2
* 208/ 19.0
36° Air (3) 230
Refrigerated Dome 200 18° 36° 28° 250
The refrigerated storage acts as a slave to the RGSSFP main case, when the refrigerated storage is self contained, the Condensi
ng unit is increased to handle both. The condensing
unit takes up 4' of the usable space in the refrigerated storage. When it is self contained, subtract 4' from the overall lengt
h of the case to result in available usable space. (8' case is
left with 4' usable storage after self cont.).
RGSSFP Wedges
45° Inside 1950 18° 36° 28° 175 - Forced 7" x 20° 40 min. .33 .6 - .56 top only - -
Total Air (1) (3) .56 top & one shelf
1.12 top & two shelves
45° Outside 1950 18° 36° 28° 175 - Forced 7" x 20° 40 min. .33 .6 - .56 no top - -
Total Air (1) (3) .56 top & one shelf
1.12 top & two shelves
90° Inside 3900 18° 36° 28° 175 - Forced 7" x 20° 40 min. .33 .6 - .56 top only - -
Total Air (1) (3) .56 top & one shelf
1.12 top & two shelves
90° Outside 3900 18° 36° 28° 175 - Forced 7" x 20° 40 min. .33 .6 - .56 top only - - -
Total Air (1) (3) .56 top & one shelf
1.12 top & two shelves
HUSSMANN CHINO CASE SPECIFICATIONS 12/99
NOTES: These merchandisers have been designed for use in stores where temperatures and humidity are maintained at or below 75°F and 55%RH. Stores are responsible for setting their cases appropriately in conditions which vary from the above.
The number of defrosts and/or the duration may vary for cases displaying products for which they were not designed. Italicized
data indicates EPR equipment.
•Hussmann Chino reserves the right to change or revise case specifications and design in connection with any feature of our pro
ducts without notice. Such changes do not entitle the buyer to corresponding changes, improvements, additions, or
replacement of equipment previously sold or shipped. These changes may also affect the loads applicable to a particular case,
therefore always check the serial plate at the back of the case and/or consult the factory for the current loads for your
particular equipment.
INQUIRIES? Technical (800) 395-9229 X2133 (Electrical ) x2126 (Refrigeration) Service (800) 395-2320 Parts and Warranty Information (800) 395-9229 X2131