CD10022 CD20030
CD10522 CD20530
Installation: General
After the carton has been removed from the
dispenser, the legs may be installed.
Place flat portions of the carton on the floor
behind the dispenser and lay the dispenser
down on its back.
Thread the legs into the base of the dispenser.
Be sure that the legs are screwed in all the way.
Turn the leg levelers in all the way.
Move the dispenser to an upright postion and set
it in the location where it will be installed. Note
where the drain lines and electrical connections
will be made.
Drain:
The dispenser has a 3/4” FPT drain fitting at the
bottom center of the back panel. Connect 3/4”
rigid tubing to this connection, a vent is
recommended for most installations. Route the
drain tubing to the building drain. Follow all
applicable plumbing codes.
Because the tubing will be very cold,
insulation is recommended.
Electrical:
There is an electrical junction box on the lower
back panel.
Make the electrical connections there. Follow all
applicable electrical codes. Use a licensed
electrician.
The dispenser must be installed so that it is a
separate piece of equipment from the ice
machine. The drains and electrical supply
must be separate.
3
NOTE
Remove any packaging material
from inside the storage bin. Retain
keys for later use.
Check that gasket tape is on the
top outside edge of the dispenser
where the ice machine will rest.