Trouble RemedyProbable Cause
DISPENSED PRODUCT
PRODUCES FOAM AS IT
LEAVES DISPENSING VALVE.
(contd)
F. Dirty water supply. F. Check water filter. Replace
cartridge (see NOTE).
NOTE: If water supply is dirty, be sure to flush lines and
carbonator carbonated water tank completely. It may be necessary
to remove lines to the carbonated water tank, invert the tank, then
flush tank and all inlet lines to remove any foreign particles or dirt.
NO PRODUCT DISPENSED
FROM ALL DISPENSING
VALVES
A. No electrical power to Unit. A. Plug in Unit power cord or check
for blown power fuse or tripped
circuit breaker. (Note: Fuse or
circuit breaker are not part of
Unit.)
B. Disconnected dispensing
valves power cord.
B. Connect dispensing valves power
cord.
C. Disconnected or broken wiring
to dispensing valveS.
C. Connect or replace wiring.
D. Inoperative 115 /24 VAC
transformer.
D. Replace transformer.
ONLY CARBONATED WATER
DISPENSED.
A. Out of syrup A. Replenish syrup supply as
instructed.
B. Inoperable dispensing valve. B. Repair dispensing valve.
C. Dispensing valve syrup flow
control not properly adjusted.
C. Adjust dispensing valve syrup
flow control (Water-to-Syrup
‘‘Ratio’’) as instructed.
D. Dispensing valve syrup flow
control or syrup lines
restricted.
D. Sanitize syrup system as
instructed.
ONLY SYRUP DISPENSED. A. Plain water inlet supply line
shutoff valve closed.
A. Open plain water inlet supply line
shutoff valve.
B. Carbonator not operating. B. Repair carbonator.
TROUBLESHOOTING REFRIGERATION SYSTEM
COMPRESSOR DOES NOT
OPERATE.
A. Ice bank sufficient. A. Refrigeration not called for.
B. Ice bank control board has
2-minute time delay.
B. Wait 2-minutes for compressor to
start.
C. Unit power cord unplugged or
drop-in refrigeration assembly
power cord unplugged.
C. Plug in Unit power cord or plug in
refrigeration assembly power
cord.
D. No power source (blown fuse
or tripped circuit breaker).
D. Replace fuse or reset circuit
breaker. (Note: Fuse or circuit
breaker are not part of Unit.)
E. Low voltage. E. Voltage must be at least 103 volts
at compressor terminal when
compressor is trying to start.
F. Loose, disconnected, or
broken wiring.
F. Tighten connections or replace
broken wiring.