Cornelius SID851W/250S-BC Ice Maker User Manual


 
3
90914
IMPORTANT: To ensure proper ice maker operation and also to reduce the frequency of water-related
service problems, a water filter should be installed. Remcor recommends the use of one of the
following basic systems:
1. Everpure, Inc. 2. System IV
660 No. Blackhawk Drive 16632 Burke Lane
Westmont, IL 60559 Huntington Beach, CA 92647
(708) 654-4000 (714) 842-4221
Insurlce Twin System #9320-42 Basic Water System #B1000
For specific recommendations on these filter systems for your local conditions, consult with a distributor in your
area or contact the filter manufacturer.
Models SID851/250S & SID851/250S-B
Connect two (2) 3/4? IPS (or equal) drain lines to the 3/4? threaded drain connections at the lower rear of the
unit. These lines must pitch downward to an open drain and must contain no traps or improper drainage will
result.
Model SID851/250S-BC
A 1? OD tubing drain elbow is provided at the bottom of the unit for the sink drain. Connect this elbow to a 7/8?
ID plastic drain tube.
A 3/4? IPS threaded drain connection for the ice maker is also provided at the bottom of the unit. Connect this
to a 3/4? IPS drain line (or equal).
These lines must pitch downward to an open drain and must contain no traps or improper drainage will result.
NOTE: In areas where consistently warm water temperatures are encountered, the use of a Remcor Pre-
Cooler in the water line is recommended to maximize the ice production of this unit. Contact Remcor
for more information on this product.
2. Electrical
A 4 x 2 junction box is located at the rear of the unit for the supply hook-up. Connect the ice maker to its
own circuit per the national electric code and local code. See SPECIFICATIONS for ampacity and fuse
size.
IMPORTANT: The wire size must be adequate for the ampacity rating, and the supply voltage must be
within a range of ± 10% for proper ice maker operation.
NOTE: The units require a 3 wire system plus earth ground for proper operations.
FIGURE 1. ELECTRICAL WIRING INSTALLATION INSTRUCTIONS
115/208-230V
1 PHASE
60 HERTZ
SUPPLY CONDUIT
BLACK (HOT)
RED (HOT)
WHITE (NEUTRAL)
GREEN (GROUND)