10
GB
GRILL
MAIN
OVEN
LEFT
FRONT
BURNER
RIGHT
REAR
BURNER
LEFT
REAR
BURNER
RIGHT
FRONT
BURNER
TIMER*
ELECTRONIC*
IgGNITION
BUTTON
Control Panel
Control Knobs for the gas burners
The position of the gas burner controlled by each
one of the knobs is shown by a solid ring
. To light
one of the burners, hold a lighted match or lighter
near the burner and, at the same time, press down
and turn the corresponding knob counter clockwise
to the maximum
-
setting. Each burner can be
operated at its maximum, minimum or intermediate
power. Shown on the knob are the different symbols
for off
(the knob is on this setting when the symbol
corresponds with the reference mark on the control
panel), for maximum
-
and minimum
+
. To obtain
these settings, turn the knob counter clockwise with
respect to the off position. To turn off the burner,
turn the knob clockwise until it stops (corresponding
again with the
symbol).
Electronic Ignition for the Gas Ho b*
This device operates when a slight pressure is
applied to the button marked with
symbol. To
light a specific burner just press the button
while
pushing the corresponding knob all the way in and
turning it counter-clockwise until it lights. For
immediate lighting, first press the button
and then turn the knob.
Should t he burner flames accidentally go out,
turn off the control knob and wait at least 1
minute before trying to relight.
Models
with Hob Gas Burner Safety Devices to
Prevent Leaks *
These models can be identified by the presence of
the device itself.
Since the hob burners are equipped with a safety
device, you must hold the control knob in for about
3-7 seconds after the burner has been lighted to
allow the gas to pass until the safety thermocouple
has heated.
Timer *
To use the timer, the buzzer must be wound up by
turning the knob one full turn clockwise; then turn it
back to the desired time so that the number of
minutes on the knob matches the reference mark on
the panel.
* (only available on certain models)
HOB GAS BURNER
SAFETY DEVICE
ELECTRONIC
LIGHTING DEVICE