The appliance must only be installed by a
competent person. In the UK, CORGI registered
installers undertake to work to safe and
satisfactory standards.
Before moving your cooker check that it is cool, and
switch off at the cooker control unit. Movement of
your cooker is most easily achieved by lifting the
front as follows:
Open the grill door sufficiently to allow a comfortable
grip on the underside front edge of the oven roof,
avoiding any grill elements.
Take care in moving the
cooker as it is heavy. Take
care to ensure that any floor
covering is not damaged. (see
figure)
Splashplate optional, apply to
Parts Department (see Back
Cover for contact number.)
The following instructions should be read by a
qualified technician to ensure that the appliance is
installed, regulated and technically serviced
correctly in compliance with current regulations.
remember to unplug the appliance from the
mains before regulating the appliance or carrying
out any maintenance work.
Positioning
this unit may be installed and used only in
permanently ventilated rooms according to the
British Standards Codes Of Practice: B.S. 6172/B.S.
5440, Par. 2 and B.S. 6891 Current Editions. The
following requirements must be observed:
a. The cooker should not be installed in a bed sitting
room with a volume of less than 20m
3
. If it is
installed in a room of volume less than 5m
3
an air
vent of effective area of 110cm
2
is required, if it is
installed in a room of volume between 5m
3
and
10m
3
a supplementary airvent area of 50cm2 is
required, if the volume exceeds 11m
3
no airvent is
required. However, if the room has a door or a
window which opens directly to the outside no air
vent is required even when the volume is between
5m
3
and 11m
3
.
b. During prolonged use of the appliance you may
consider it necessary to open a window to the
outside to improve ventilation.
c. If there are other fuel burning appliances in the
same room, B.S.5440 Part 2 Current Edition,
should, be consulted to determine the requisite air
vent feet in the plinth (900mm - 915mm). Adjust
the feet by tilting the cooker from the side. Then
install the product into position.
This appliance must not be fitted on a platform.
The cooker is designed to fit between kitchen
cabinets spaced 500mm apart. The space either
side need only be sufficient to allow withdrawal of
the cooker for servicing. It can be used with
cabinets one side or both as well as in a corner
setting. It can also be used free-standing.
Adjacent side walls which project above hob level,
must not be nearer to the cooker than 150mm or
65mm (Fig. A) and should be protected by heat
resistant material. Any overhanging surface or
cooker hood should not be nearer than 750mm.
(Fig.A)
a.The cooker may be located in a kitchen, a
diner or bed sitting room, but not in a bathroom or
shower room.
b.The hoods must be installed according to the
requirements in the hood handbook.
c.The wall in contact with the back of the cooker
must be of flameproof material.
d.The cooker is fitted with a safety chain that must
be attached to a hook, secured to the wall behind
the appliance.
some models can have their gas connection
inverted. It is important to make sure the safety
chain is always situated on the side which
corresponds to the hose holder (Fig. B).
65 mm min
500 mm min
400 mm min400 mm min
750 mm min
Tall cupboard on the left hand
side of 50cm gas cooker
65 mm min
65 mm min
150 mm min
500 mm min
750 mm min
Tall cupboard on the right hand
side of 50cm gas cooker
Fig. A
Fig. B
Installation