Ingersoll-Rand 67161-() Garbage Disposal User Manual


 
67161ĆXPAGE 6 OF 8
PROGRAMMING (continued)
SETTING
THE
LOCK
STATUS
STEP
6
SETTING
THE
RELAYS
SETTING
THE
PRESETS
PRESS DISPLAY REMARKS
LOCK
This section sets up the relay information.
ENTER
ENTER
Press the ``PROG" key to choose ``TOT" (relay B assigned
to total) or ``PREW" (relay B assigned to prewarn). Press
``enter" when the desired choice is displayed.
ENTER
PRE A
PROG
Key in the lock code (see programming step 4) by pressing
the keys under the digits to be changed. Press the ``enter"
key to enter the displayed code.
After the code is entered, the unit will display ``LOC" (unit
is locked)or ``UN LOC"(unit is unlocked). Thismessage will
be displayedfor approximately 3secondsbeforetheunit reĆ
turns to the run mode.
PROG
PROG
PROG
PROG
PROG
PROG
This will only appear if ``TOT" is selected. This is the duraĆ
tion (.01 - 99.99 seconds) that relay ``B" will remain enerĆ
gized. If 00.00 is selected, the relay will latch until reset.
PRE A = Preset A (batch amount). The set point at which
output ``A" will drop out after started. If the displayed value is
not the desired preset, press the key(s) under the digit to be
changed.
PRE B = Preset B
a) tot selected The set point at which output ``B" will enĆ
ergize.
b) PrEw selected The number of countsbefore batch ends
that output ``B" will drop out.
If the displayed value is not the desired preset, press the
key(s) under the digit to be changed.
flashes
followed by:
or
or
## ##
followed by
last PRE A
entered