Jackson 200LT Dishwasher User Manual


 
200 Series Technical Manual
7610-100-45-00 Rev. E (02/10/2006)
SECTION 1: SPECIFICATION INFORMATION
OPERATING CAPACITIES
PERFORMANCE/CAPABILITIES
OPERATING CAPACITY (RACKS/HOUR)
RACKS PER HOUR 57
DISHES PER HOUR 1425
GLASSES PER HOUR 1425
OPERATING CYCLE (SECONDS)
WASH TIME 45
RINSE TIME 11
TOTAL CYCLE 58
TANK CAPACITY (GALLONS)
WASH TANK (MINIMUM) 8.0
BOOSTER TANK 3.0
WASH PUMP CAPACITY
GALLONS PER MINUTE 150
TEMPERATURES
WASH---°F (MINIMUM) 150
RINSE---°F (MINIMUM) 180
WASH---°F (MINIMUM) (200 LT) 130
RINSE---°F (MINIMUM) (200 LT) 130
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to
change without notice.
STEAM REQUIREMENTS
COIL SIZE 3/4”
STEAM FLOW PRESSURE (P.S.I.) 10-20
CONSUMPTION @ 15 P.S.I. (LBS/HR) 45
WATER REQUIREMENTS (MINIMUM)
INLET TEMPERATURE (200) 180°F
INLET TEMPERATURE (200B)(40° Rise) 140°F
INLET TEMPERATURE (200B)(70° Rise) 110°F
INLET TEMPERATURE (200LT) 140°F
INLET TEMPERATURE (200S) 110°F
GALLONS PER HOUR 52.2
GALLONS PER RACK 0.92
WATER LINE SIZE NPT 3/4”
DRAIN LINE SIZE NPT 1 1/2”
FLOW PRESSURE P.S.I. (Optimum) 20A5
MINIMUM CHLORINE REQUIRED (PPM)(200LT) 50
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HP 1
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition.
Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical
service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These
numbers are provided in this manual simply for reference
and may change without notice at any given time.
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
MODEL VOLTS PH HZ RATINGS AMPS CIRCUIT
200B 208 1 60 12KW@230 72 A 90 AMP
200B 230 1 60 12KW@230 79 A 100 AMP
200B 208 3 60 12KW@230 40 A 50 AMP
200B 230 3 60 12KW@230 44 A 60 AMP
200B 460 3 60 12KW@230 22 A 25 AMP
200B 208 1 60 14KW@230 79 A 100 AMP
200B 230 1 60 14KW@230 87 A 110 AMP
200B 208 3 60 14KW@230 44 A 60 AMP
200B 230 3 60 14KW@230 49 A 70 AMP
200B 460 3 60 14KW@230 25 A 36 AMP
200 208 1 60 N/A 29 A 40 AMP
200 230 1 60 N/A 31 A 40 AMP
200 208 3 60 N/A 15 A 20 AMP
200 230 3 60 N/A 16 A 20 AMP
200 460 3 60 N/A 8 A 15 AMP
200/LT 208 1 60 N/A 29 A 40 AMP
200/LT 230 1 60 N/A 31 A 40 AMP
200/LT 208 3 60 N/A 15 A 20 AMP
200/LT 230 3 60 N/A 16 A 20 AMP
200/LT 460 3 60 N/A 8 A 15 AMP
200S 208 1 60 N/A 7 A 15 AMP
200S 230 1 60 N/A 7 A 15 AMP
200S 208 3 60 N/A 4 A 15 AMP
200S 230 3 60 N/A 4 A 15 AMP
200S 460 3 60 N/A 4 A 15 AMP
2