NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These numbers are provided in this manual simply for reference
and may change without notice at any given time.
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
MODEL VOLTS PH
HZ RATINGS AMPS CIRCUIT
AJ-44TE 208 1 60 N/A 97 A 125 AMP
AJ-44TE 230 1 60 N/A 89 A 125 AMP
AJ-44TE 208 3 60 N/A 57 A 80 AMP
AJ-44TE 230 3 60 N/A 49 A 70 AMP
AJ-44TE 460 3 60 N/A 25 A 35 AMP
AJ-44TG 208 1 60 N/A 12 A 15 AMP
AJ-44TG 230 1 60 N/A 12 A 15 AMP
AJ-44TG 208 3 60 N/A 8 A 15 AMP
AJ-44TG 230 3 60 N/A 8 A 15 AMP
AJ-44TG 460 3 60 N/A 5 A 15 AMP
AJ-44TS 208 1 60 N/A 11 A 15 AMP
AJ-44TS 230 1 60 N/A 11 A 15 AMP
AJ-44TS 208 3 60 N/A 7 A 15 AMP
AJ-44TS 230 3 60 N/A 7 A 15 AMP
AJ-44TS 460 3 60 N/A 4 A 15 AMP
AJ-66TE 208 1 60 N/A 103 A 150 AMP
AJ-66TE 230 1 60 N/A 95 A 125 AMP
AJ-66TE 208 3 60 N/A 61 A 80 AMP
AJ-66TE 230 3 60 N/A 52 A 70 AMP
AJ-66TE 460 3 60 N/A 26 A 35 AMP
AJ-66TG 208 1 60 N/A 18 A 25 AMP
AJ-66TG 230 1 60 N/A 18 A 25 AMP
AJ-66TG 208 3 60 N/A 12 A 15 AMP
AJ-66TG 230 3 60 N/A 12 A 15 AMP
AJ-66TG 460 3 60 N/A 7 A 15 AMP
AJ-66TS 208 1 60 N/A 17 A 25 AMP
AJ-66TS 230 1 60 N/A 17 A 25 AMP
AJ-66TS 208 3 60 N/A 11 A 15 AMP
AJ-66TS 230 3 60 N/A 11 A 15 AMP
AJ-66TS 460 3 60 N/A 6 A 15 AMP
AJ-80TE 208 1 60 N/A 106 A 150 AMP
AJ-80TE 230 1 60 N/A 97 A 125 AMP
AJ-80TE 208 3 60 N/A 63 A 80 AMP
AJ-80TE 230 3 60 N/A 58 A 80 AMP
AJ-80TE 460 3 60 N/A 29 A 40 AMP
AJ-80TG 208 1 60 N/A 19 A 25 AMP
AJ-80TG 230 1 60 N/A 19 A 25 AMP
AJ-80TG 208 3 60 N/A 13 A 20 AMP
AJ-80TG 230 3 60 N/A 13 A 20 AMP
AJ-80TG 460 3 60 N/A 7 A 15 AMP
AJ-80TS 208 1 60 N/A 19 A 25 AMP
AJ-80TS 230 1 60 N/A 19 A 25 AMP
AJ-80TS 208 3 60 N/A 13 A 20 AMP
AJ-80TS 230 3 60 N/A 13 A 20 AMP
AJ-80TS 460 3 60 N/A 7 A 15 AMP
AJ-44T Series Technical Manual 7610-003-07-21
Issued: 03-21-2006 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
3