4. When replacing the coil, ensure that when removing the coil wire
cover that care is taken not to damage the wires inside. Using the
medium flathead screwdriver, gently use it to open the cover
enough to where it could be pulled off.
5. Once the coil wire cover has been removed and set to the side,
take the internal wires and pull them out straight.
6. Remove the wire nuts from the wires and separate them.
7. Using a pair of channel locks, gently loosen the conduit retain
-
ing ring for the conduit nut. Once it is loosened, use your fingers to
unscrew and remove it.
8. Pull the conduit away and discard the bad coil. Take the new coil
and attach the conduit, reinstall & tighten the conduit nut, and pullg
the wires through so that you will be able to wire the valve back up.
9. Reconnect the wires from the conduit to the wires from the sole
-
noid as they had been connected previously. Ensure that the wire
nuts are on tight.
10. Slide the coil wire cover back on, taking care not to damage the
wires.
11. If you are done performing maintenance on the valve, continue
on to step 23. Otherwise, please go on to step 12.
12. To remove the valve bonnet, grasp it with the jaws of the pipe
wrench and turn to the left. Note:
on some models you may have
www.jacksonmsc.com
Parker Style Solenoid Valve Repair Kit Instructions
Revision A (04/15/2005)
3
Prying open the coil wire cover
Straightening the wires
Loosening the conduit nut
Removing the wire nuts
Loosening the valve bonnet