Jenn-Air CVG2420 Cooktop User Manual


 
Check the following list to be sure a service call is reallynecessary.
If surface burner fails to light:
check to be sure unit is properly connected to power supply.
check for a blown circuit fuse or a tripped main circuit breaker.
check to be sure burner is correctly adjusted for your type of gas.
check to be sure burner porLsare not clogged.
check to be sure igniter is clicking. If ignLterdoesn't click, turn control knob
OFE
check to be sure pressure regulatoris set for the correct fuel.
check to be sure inlet pressure is adequate. (5" of water column for natural gas
and 10" of water column for LP gas).
If the flame is uneven:
burner ports may be clogged.
flame setting may need to be adjusted.
If surface burner flame lifts off the ports:
contactan authorized Service Contractor for Jenn-Air products.
If surface burner flame is yellow in color:
contact an authorized Service Contractor for Jenn-Air products.
If ventilation system is not capturing smoke efficiently:
check on cross ventilation in room or make up air.
outside wallcap may be trapped shut.
cooktop may be improperly installed (see p. 9); check installation instructions.
IBmJENN-AIR
403 WEST FOURTH STREET NORT}t * N EWTON_ IA 50208