Check the following list to be sure a service call is reallynecessary.
If surface burner fails to light:
• check to be sure unit is properly connected to power supply.
• check for a blown circuit fuse or a tripped main circuit breaker.
• check to be sure burner is correctly adjusted for your type of gas.
• check to be sure burner porLsare not clogged.
• check to be sure igniter is clicking. If ignLterdoesn't click, turn control knob
OFE
• check to be sure pressure regulatoris set for the correct fuel.
• check to be sure inlet pressure is adequate. (5" of water column for natural gas
and 10" of water column for LP gas).
If the flame is uneven:
• burner ports may be clogged.
• flame setting may need to be adjusted.
If surface burner flame lifts off the ports:
• contactan authorized Service Contractor for Jenn-Air products.
If surface burner flame is yellow in color:
• contact an authorized Service Contractor for Jenn-Air products.
If ventilation system is not capturing smoke efficiently:
• check on cross ventilation in room or make up air.
• outside wallcap may be trapped shut.
• cooktop may be improperly installed (see p. 9); check installation instructions.