Burner Ignition And
Auto-Reignition
This appliance is equipped for e lectronic auto-reignition by
means of a spark igniter located at the rear of each
burner. The burners are designed to light at any valve
rotation that admits sufficient gas flow to support a flame
and to automatically relight following a l oss o f flame due
to a draft or other adverse condition. This feature is
provided as a convenience and is not intended as a safety
feature.
This appliance has no air shutters. Primary air
adjustments are unnecessary. The burners are designed
to provide optimum aeration for all gases without air
shutters. When operating properly, burners should
produce clearly defined, even blue f lames. If the flames
have yellow tips or are haz y and otherwise appear to
have insufficient air, obtain the services of a qualified
service technician.
Specified input rates are as shown below.
BURNER
LOCATION Hi Lo
Right Front 17K 1700
Right R ear 9.2K 1050
Left Front 17K 1700
Left Rear 5K 600
INPUT RATES - NATURAL GAS (BTU/HR)
JGCP430ADP
JGCP636ADP and JGCP648ADP
BURNER
LOCATION Hi Lo
Right Front 17K 1700
Right R ear 9.2K 1050
Center Front 9.2K 1050
Center Rear 5K 600
Left Front 17K 1700
Left Rear 5K 600
INPUT RATES - NATURAL GAS (BTU/HR)
Model JGCP648ADP includes 1300 Watt Electric
Griddle Accessory.
Required Adjustments At Time
Of Installation
The installation of this appliance must conform with local
codes, or in the absence of local codes, with the latest
edition of the National Fuel Gas Code ANSI Z223.1 USA
or current CAN/CGA-B149 INSTALLATION CODE.
V This appliance was manufactured for use with N atural
Gas. If LP gas is the fuel of c hoice, follow the
conversion to LP procedure found in t he installation
instructions.
V Test all external connections for gas leaks. Never test
for gas leaks with an open flame.
V Test all electrical connections.