Before carrying out any maintenance or
cleaning isolate the cooker hood from the
mains supply.
Charcoal Filters
In the recirculation mode the charcoal filters absorb
smells and unwanted odours.
The charcoal filters cannot be cleaned, we recommend
they should be replaced approximately every three
months or more often if the hood is used for more
than three hours per day.
To Remove/Replace the Char-
coal Filters
1. First remove the metal grease filters.
2. Remove the saturated activated charcoal filter by releasing
the fixing hooks as illustrated.
3. Position the new charcoal filter in the position marked
and while holding the filter replace the fixing hooks as
illustrated
This appliance can be a possible fire hazard if
the grease and charcoal filters are not cleaned
and replaced as recommended.
Changing the Light Bulb
1. Remove the screw fastening the lamp cover.
2. Pull the lamp cover downwards.
3. Rotate the light bulb anti-clockwise to unscrew.
4. To replace the light bulb insert a replacement into the
holder then rotate the bulb clockwise into position. Ensure
you take care not to overtighten the bulb.
5. Replace the lamp cover.
If the light bulb fails to function check that the bulb is fully
screwed into the holder. If bulb failure has occurred then
it should be replaced with a 220-240 Volt 40W clear globe
shaped bulb with a small E14 screw thread.
Replacement filters and light bulbs can be ob-
tained from your local Service Force Centre.