PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-NLC250/NLC250
Testedand certified by NSF International againstANSI/NSF Standard
42 for the reductionof Chlorine (ClassI) Tasteand Odor and against
ANS/NSF Standard53 forthe reducton of Lead, Cysts andTurbd ty.
Capacity; 250Gallons (946Liters)
Service Flow Rate: 0.5 GPM (t,89 L/min,) @60 psi.
Substance Reduction U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 1.9 mg/L N/A 0.04 mg/L N/A 97.9% 994707
Particulate N/A 610,000/mL* N/A 154/mL N/A 99.97% 994711
Contaminant U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Reduction MCL Influent Effluent Effluent Reduction Reduction Number
Cyst 99.95%** 89,250/mL* 6/mL 2.3/mL 99.993% 99.997% 994710
Turbidity 0.5 NTU 29 NTU 0.1 NTU 0.09 NTU 99.5% 99.69% 994710
Lead: @pH 6.5 0.015 mg/L 0.16 mg/L*** 0.001 mg/L 0.001 mg/L 99.4% 99.4% 994708
Lead: @pH 8.5 0.015 mg/L 0.16 mg/L*** 0.002 mg/L 0.001 mg/L 98.8% 99.4% 994709
Base Grille Water Filtration System Model WF-LC400/LC400
Testedand certified by NSF International againstANSI/NSF Standard
42 for the reductionof Chlorine (ClassI) Tasteand Odor and against
ANS/NSF Standard53 forthe reducton of Lead, Cysts andTurbd ty.
Capacity; 400 Gallons (15t4 Liters)
Service Flow Rate: 0.5 GPM (t,89 L/min,) @60 psi.
Substance Reduction U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 2.0 mg/L N/A 0.04 mg/L N/A 98% 994707
Particulate N/A 610,000/mL* N/A 154/mL N/A 99% 994711
Contaminant U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Reduction MCL Influent Effluent Effluent Reduction Reduction Number
Cyst 99.95%** 89,250/mL* 6/mL 2.3/mL 99.993% 99.997% 994710
Turbidity 0.5 NTU 29 NTU 0.12 NTU 0.09 NTU 99.59% 99.69% 994710
Lead: @pH 6.5 0.015 mg/L 0.16 mg/L*** 0.001 mg/L 0.001 mg/L 99.4% 99.4% 994708
Lead: @pH 8.5 0.015 mg/L 0.16 mg/L*** 0.002 mg/L 0.001 mg/L 98.8% 99.4% 994709
• It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
• Model WF-NLC250 Change cartridge at least every 6-9
months. Use replacement cartridge NLC 250, part# 9902.
2000 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Model WF-LC40O The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400, part#
9902. 2000 suggested retail price of $39.95 U.S.A./S49.95
Canada.
• The product is for cold water use only.
• Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
• Refer to the "Assistance or Service" section for the
Manufacturer's name, address and telephone number.
• Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application GuidelinesP_/ater Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
*Test requirement is at least 1OO,OOOparticles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is O.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.
24