Kenmore 630.13952 Dishwasher User Manual


 
Repair
702_58300000149896_ara_en_b
VF. 2-piece drain hose connection
Drain hoses come in two pieces, an external (customer) drain hose and an
internal drain hose. The 90º elbow of the external hose is connected to the
outlet of the internal hose (pointing toward the drain) and is held in place by a
hose clamp.
To remove the internal drain hose, remove a white plastic hose lock and pull the
hose from the water level control.
VG. Drain pumps
To access pump, disconnect inlet hose and pump harness. To remove pump,
(1) pull latch (on circular collar), (2) rotate pump clockwise (cw) ~ 1/8 turn and
(3) pull out pump. To install new pump, insert @ 2:00 position & rotate
counterclockwise (ccw).
VH. Dispensers
Dispens
ers can be accessed from the front by removing the outer door.
Tools needed: Small flat blade and T-20 Torx screwdrivers.
To remove dispensers
1. Remove outer door -- section VA.
2. Disconnect wire harnesses from dispenser. Don’t remove the cable tie
keeping the harness away from the dispenser. It must be replaced if it’s
removed.
3. Using a small flat blade screwdriver, push the six inner door tabs holding
the dispenser.
4. Carefully push the dispenser in toward the inside of the inner door.